LumiDigit Troubleshooting
LCD does not
display information
- Possible Cause: Console is not plugged in
- Possible Solution: Plug in console with supplied 9VDC power
supply
Both sides of the
sign are blank
- Possible Cause: No message was sent to
sign
- Possible Solution: 1. Send message to sign following directions in
operations manual
- Possible Cause: No power to sign
- Possible Solution: Turn on power to the sign;
Check fuses/ wiring
Only one side of sign displays message
- Possible Cause:Connections are not
connected correctly
- Possible Solution: Check all connections to sign
Messages shows
lines out of sequence
and
2 or 3 size fonts
are not displayed
correctly
- Possible Cause: Line outputs are connected
incorrectly
- Possible Solution Side A:
Connect line 1 (top) to output 1.
Connect line 2 (middle) to output 2.
Connect line 3 (bottom) to output 3
- Possible Solution Side B:
Connect line 1 (top) to output 5.
Connect line 2 (middle) to output 6.
Connect line 3 (top) to output 7
When showing time,
date or temperature,
sign shown boxes or
nothing
- Possible Cause: Time and Date was not set
in console and sent to sign
- Possible Solution: Set time and date in console and send to sign
- Possible Cause: Time and Temperature
Probe is not connected
- Possible Solution: Connect time and temp probe to J5 in the time
and temp module
Message does not
not change
- Possible Cause: Message was changed, in
console but never sent to sign
- Possible Solution: After entering message, go to the first screen
and arrow down to “Send Message to Sign”
- Possible Cause: Signal did not get to sign -
received “Error - Send Again”
message
- Possible Solution: Make sure that the console is in direct line
of sight with sign and send again. If behind
a window, try from another location or from
outside. The window in the store may have a
uv coating or other elements that may interfere
with the radio signal. If this is the case, call
Everbrite for alternate antenna solutions
Console is not
displaying message
screens
- Possible Cause: “Price/Message” button was
not pressed.
- Possible Solution: Press Price/Message button on console. All
further activity will now be controlled by the
supplied keyboard. READ THE OPERATIONS MANUAL
Line entry will
only allow some of
the message to be
entered
- Possible Cause: Message entered is longer
than the line allows
- Possible Solutions:
- Shorten message
- Select “TRAV EL” for the mode before text is
entered.
- Select a lower font number (1 is smallest,
3 is largest) - the smaller the font, the more
characters can fit on a line.
All 3 font sizes are
not available
- Possible Cause: Single ine signs can only display 1 line of text. 2 line signs can only display 1 line or 2 lines of text
- Possible Solution: None. A larger message center may
be purchased from Everbrite. For more information, refer to manual
- Possible Cause: When operating a sign, the
size used in line one will effect
the sizes available in lines 2
and 3. The font sizes available
will be adjusted by the prior
lines input or by sign setup
- Possible Solution: Read the owners manual to better understand
how to enter a message properly
Messages entered
in console run off the
edge of the sign
- Possible Cause: Sign may be incorrectly
setup
- Possible Solution: Measure the message area (area in between
the vinyl) to get an accurate size.
Columns:
Divide the length of inches by 9. Round this
number down to the nearest inch and multiply
by 8. This will give you the amount of columns
in your sign. Select the closest number in
Sign Setup - do not select a higher number of
columns than your calculation.
Lines:
The EMC is available in 1, 2 or 3 line
configurations. The window height of a 1
line is approx 10”, 2 line window height is
approximately 20”, 3 line window height is
approximately 30”.
Message will need to be re-entered and
sent to sign to ensure that correct setup
was selected.
If the sign is too high or far away to measure,
simply change sign setup until message
is displayed correctly. For example, if the
message almost fits, select the next lower
number for columns. If the message repeats
itself, select the next higher option for
columns
- Possible Cause: If DAY and DATE run off the
edge, select either Day on one
line and DATE on another line
- Possible Solution: If DAY and DATE run off the edge, select
either Day on one line and DATE on another
line